UT-141C-TP
|
Semi-Rigid Coaxial Cable
|
|
MECHANICAL CHARACTERISTICS
|
|
|
Outer Conductor Diameter, inch (mm) |
0.141+0.002 / -0.001 (3.581+0.0508 / -0.0254) |
Dielectric Diameter, inch (mm) |
0.1175 (2.985) |
Center Conductor Diameter, inch (mm) |
0.0359+0.0010/-0.0004 (0.91+0.0254/-0.0102) |
Maximum Length, feet (meters) |
20 (6.1) |
Minimum Inside Bend Radius, inch (mm) |
0.075 (1.91) |
Weight, pounds/100 ft. (kg/100 meters) |
3.17 (4.72) |
|
ELECTRICAL CHARACTERISTICS
|
|
|
Impedance, ohms |
50+/-1.0 |
Frequency Range GHz |
DC-34 |
Velocity of Propagation % |
70 |
Capacitance, pF/ft. (pF/meter) |
29 (95.1) |
Typical Insertion Loss, dB/ft. (dB/meter) and Average Power Handling, Watts CW at 20 degrees Celsius and Sea level |
Frequency |
Insertion Loss |
Power |
0.5 GHz 1.0 GHz 5.0 GHz 10.0 GHz 20.0 GHz |
0.08 (0.26) 0.11 (0.37) 0.28 (0.91) 0.42 (1.36) 0.64 (2.09) |
483.5 336.2 140.4 94.6 62.7 |
Corona Extinction Voltage, VRMS @ 60 Hz |
1900 |
Voltage Withstand, VRMS @ 60 Hz |
5000 |
|
ENVIRONMENTAL CHARACTERISTICS
|
|
|
Outer Conductor Integrity Temperature, Deg Celsius |
175 |
Maximum Operating Temperature, Deg Celsius |
125 |
|
Outer Conductor |
Tin plated Copper |
Dielectric |
PTFE |
Center Conductor |
SPC |
|
|