UT-085-SS-SS
|
Semi-Rigid Coaxial Cable
|
|
MECHANICAL CHARACTERISTICS
|
|
|
Outer Conductor Diameter, inch (mm) |
0.0865 +/- 0.001 (2.197 +/- 0.0254) |
Dielectric Diameter, inch (mm) |
0.006 (1.676) |
Center Conductor Diameter, inch (mm) |
0.0201 +/- 0.0005 (0.511 +/- 0.0127) |
Maximum Length, feet (meters) |
20 (6.1) |
Minimum Inside Bend Radius, inch (mm) |
0.25 (6.35) |
Weight, pounds/100 ft. (kg/100 meters) |
1.25 (1.86) |
|
ELECTRICAL CHARACTERISTICS
|
|
|
Impedance, ohms |
50 |
Frequency Range GHz |
DC-61 |
Velocity of Propagation % |
|
Capacitance, pF/ft. (pF/meter) |
29.3 (96.1) |
Typical Insertion Loss, dB/ft. (dB/meter) and Average Power Handling, Watts CW at 20 degrees Celsius and Sea level |
Frequency |
Insertion Loss |
Power |
0.5 GHz 1.0 GHz 5.0 GHz 10.0 GHz 20.0 GHz |
0.89 (2.92) 1.26 (4.13) 2.84 (9.32) 4.04 (13.25) 5.76 (18.90) |
52.4 37 16.4 11.6 8.1 |
Corona Extinction Voltage, VRMS @ 60 Hz |
1500 |
Voltage Withstand, VRMS @ 60 Hz |
5000 |
|
ENVIRONMENTAL CHARACTERISTICS
|
|
|
Outer Conductor Integrity Temperature, Deg Celsius |
225 |
Maximum Operating Temperature, Deg Celsius |
200 |
|
Outer Conductor |
304-SS |
Dielectric |
PTFE |
Center Conductor |
304-SS |
|
|