UT-070C-TP

$16.50
Price breaks per foot:

Below are the price breaks per ft. Semi-Rigid Coax Cable is sold as 5 ft. straight lengths (pieces). Maxform and M-Flex cable sold by coil / reel. Place order for total footage required. eg. 25ft=25, 100ft=100. Please email sales@tek-stock.com for qtys over 500ft

  • Buy 15 - 20 ft. and pay only $16.49 per ft.
  • Buy 25 - 45 ft. and pay only $12.11 per ft.
  • Buy 50 - 95 ft. and pay only $8.90 per ft.
  • Buy 100 - 295 ft. and pay only $7.23 per ft.
  • Buy 300 - 495 ft. and pay only $6.26 per ft.
  • Buy 500 - 995 ft. and pay only $5.33 per ft.
  • Buy 1000 or above ft. and pay only $4.16 per ft.
Current Stock:

Please contact sales@tek-stock.com

Out of Stock

 


UT-070C-TP

Semi-Rigid Coaxial Cable


MECHANICAL CHARACTERISTICS

Outer Conductor Diameter, inch (mm) 0.070+0.002/-0.001  (1.778+.0508/+0.0254)
Dielectric Diameter, inch (mm) 0.059  (1.499)
Center Conductor Diameter, inch (mm) 0.0179+/-0.0005  (0.455+/-0.0127)
Maximum Length, feet (meters) 20  (6.1)
Minimum Inside Bend Radius, inch (mm) 0.125  (3.175)
Weight, pounds/100 ft. (kg/100 meters) 0.77  (1.15)

ELECTRICAL CHARACTERISTICS

Impedance, ohms 50+/-1.0
Frequency Range GHz DC-68
Velocity of Propagation % 70
Capacitance, pF/ft. (pF/meter) 29 (95.1)
Typical Insertion Loss, dB/ft. (dB/meter)
and Average Power Handling, Watts CW at 20
degrees Celsius and Sea level
Frequency Insertion Loss Power
0.5 GHz
1.0 GHz
5.0 GHz
10.0 GHz
20.0 GHz
0.15 (0.50)
0.22 (0.71)
0.51 (1.66)
0.75 (2.44)
1.10 (3.62)
119.3
83.6
36
24.8
16.9
Corona Extinction Voltage, VRMS @ 60 Hz 1200
Voltage Withstand, VRMS @ 60 Hz 2300

ENVIRONMENTAL CHARACTERISTICS

Outer Conductor Integrity Temperature, Deg Celsius 135
Maximum Operating Temperature, Deg Celsius 100

MATERIALS

Outer Conductor Tin plated Copper
Dielectric PTFE
Center Conductor SPC

CUTAWAY