UT-034M
$18.27
Authorized Distributor for:
Below are the price breaks per ft. Semi-Rigid Coax Cable is sold as 5 ft. straight lengths (pieces). Maxform and M-Flex cable sold by coil / reel. Place order for total footage required. eg. 25ft=25, 100ft=100. Please email sales@tek-stock.com for qtys over 500ft
UT-056-STR/MA50056 |
||||||
Semi-Rigid Coaxial Cable |
||||||
|
||||||
Outer Conductor Diameter, inch (mm) | 0.056+/-0.002 (1.422+/-0.0508) | |||||
Dielectric Diameter, inch (mm) | 0.036 (0.914) | |||||
Center Conductor Diameter, inch (mm) | 7/0.004+/-0.0005 (7/0.102+/-0.0127) | |||||
Maximum Length, feet (meters) | 50 (15) | |||||
Minimum Inside Bend Radius, inch (mm) | 0.125 (3.175) | |||||
Weight, pounds/100 ft. (kg/100 meters) | 0.68 (1.01) | |||||
|
||||||
Impedance, ohms | 50+/-4.0 | |||||
Frequency Range GHz | DC-112 | |||||
Velocity of Propagation % | 70 | |||||
Capacitance, pF/ft. (pF/meter) | 29 (95.1) | |||||
Typical Insertion Loss, dB/ft. (dB/meter) and Average Power Handling, Watts CW at 20 degrees Celsius and Sea level |
Frequency | Insertion Loss | Power | |||
0.5 GHz 1.0 GHz 5.0 GHz 10.0 GHz 20.0 GHz |
0.25 (0.81) 0.36 (1.16) 0.81 (2.66) 1.16 (3.81) 1.66 (5.45) |
135 95 40 30 20 |
||||
Corona Extinction Voltage, VRMS @ 60 Hz | 1000 | |||||
Voltage Withstand, VRMS @ 60 Hz | 2000 | |||||
|
||||||
Outer Conductor Integrity Temperature, Deg Celsius | 200 | |||||
Maximum Operating Temperature, Deg Celsius | 175 | |||||
|
||||||
Outer Conductor | Copper | |||||
Dielectric | PTFE | |||||
Center Conductor | Stranded SPCW | |||||
|
||||||