UT-047-25-TP
|
Semi-Rigid Coaxial Cable
|
|
MECHANICAL CHARACTERISTICS
|
|
|
Outer Conductor Diameter, inch (mm) |
0.047 + 0.004 / - 0.003 (1.194 + 0.1 / -0.0762) |
Dielectric Diameter, inch (mm) |
0.034 (0.860) |
Center Conductor Diameter, inch (mm) |
0.020 +/- 0.0005 (0.508 +/- 0.0127) |
Maximum Length, feet (meters) |
25 (7.62) |
Minimum Inside Bend Radius, inch (mm) |
0.125 (3.175) |
Weight, pounds/100 ft. (kg/100 meters) |
0.54 (0.81) |
|
ELECTRICAL CHARACTERISTICS
|
|
|
Impedance, ohms |
25 +/- 3.0 |
Frequency Range GHz |
DC - 120 |
Velocity of Propagation % |
70 |
Capacitance, pF/ft. (pF/meter) |
58.9 (193.2) |
Typical Insertion Loss, dB/ft. (dB/meter) and Average Power Handling, Watts CW at 20 degrees Celsius and Sea level |
Frequency |
Insertion Loss |
Power |
0.5 GHz 1.0 GHz 5.0 GHz 10.0 GHz 20.0 GHz |
0.43 (1.40) 0.61 (1.99) 1.38 (4.51) 1.97 (6.47) 2.84 (9.30) |
39.6 27.9 12.3 8.6 6 |
Corona Extinction Voltage, VRMS @ 60 Hz |
850 |
Voltage Withstand, VRMS @ 60 Hz |
1500 |
|
ENVIRONMENTAL CHARACTERISTICS
|
|
|
Outer Conductor Integrity Temperature, Deg Celsius |
175 |
Maximum Operating Temperature, Deg Celsius |
150 |
|
Outer Conductor |
Tin-Plated Copper |
Dielectric |
PTFE |
Center Conductor |
SPCW |
|
|