UT-034-M
|
Semi-Rigid Coaxial Cable
|
|
MECHANICAL CHARACTERISTICS
|
|
|
Outer Conductor Diameter, inch (mm) |
0.0375+/-0.001 (0.953+/-0.0254) |
Dielectric Diameter, inch (mm) |
0.024 (61) |
Center Conductor Diameter, inch (mm) |
0.008+/-0.0005 (0.203+/-0.0127) |
Maximum Length, feet (meters) |
15 (4.57) |
Minimum Inside Bend Radius, inch (mm) |
0.05 (1.27) |
Weight, pounds/100 ft. (kg/100 meters) |
0.26 (0.39) |
|
ELECTRICAL CHARACTERISTICS
|
|
|
Impedance, ohms |
50+/-4.0 |
Frequency Range GHz |
DC-155 |
Velocity of Propagation % |
70 |
Capacitance, pF/ft. (pF/meter) |
29 (95.1) |
Typical Insertion Loss, dB/ft. (dB/meter) and Average Power Handling, Watts CW at 20 degrees Celsius and Sea level |
Frequency |
Insertion Loss |
Power |
0.5 GHz 1.0 GHz 5.0 GHz 10.0 GHz 20.0 GHz |
0.33 (1.07) 0.47 (1.53) 1.06 (3.48) 1.53 (5.01) 2.21 (7.24) |
68.3 48.1 21.2 14.8 10.3 |
Corona Extinction Voltage, VRMS @ 60 Hz |
750 |
Voltage Withstand, VRMS @ 60 Hz |
2000 |
|
ENVIRONMENTAL CHARACTERISTICS
|
|
|
Outer Conductor Integrity Temperature, Deg Celsius |
225 |
Maximum Operating Temperature, Deg Celsius |
200 |
|
Outer Conductor |
Copper |
Dielectric |
PTFE |
Center Conductor |
SPCW |
|
 |