UT-034-25-TP
|
Semi-Rigid Coaxial Cable
|
|
MECHANICAL CHARACTERISTICS
|
|
|
Outer Conductor Diameter, inch (mm) |
0.034+0.002 / -0.001 (0.864+0.0508 / -0.0254) |
Dielectric Diameter, inch (mm) |
0.023 (0.584) |
Center Conductor Diameter, inch (mm) |
0.0126+/-0.0005 (0.320+/-1.0127) |
Maximum Length, feet (meters) |
15 (4.57) |
Minimum Inside Bend Radius, inch (mm) |
0.05 (1.27) |
Weight, pounds/100 ft. (kg/100 meters) |
0.26 (0.39) |
|
ELECTRICAL CHARACTERISTICS
|
|
|
Impedance, ohms |
25+/-2.0 |
Frequency Range GHz |
DC-148 |
Velocity of Propagation % |
70 |
Capacitance, pF/ft. (pF/meter) |
58 (190.4) |
Typical Insertion Loss, dB/ft. (dB/meter) and Average Power Handling, Watts CW at 20 degrees Celsius and Sea level |
Frequency |
Insertion Loss |
Power |
0.5 GHz 1.0 GHz 5.0 GHz 10.0 GHz 20.0 GHz |
0.50 (1.64) 0.71 (2.32) 1.61 (5.27) 2.30 (7.53) 3.29 (10.81) |
25.4 17.9 7.9 5.6 3.9 |
Corona Extinction Voltage, VRMS @ 60 Hz |
200 |
Voltage Withstand, VRMS @ 60 Hz |
500 |
|
ENVIRONMENTAL CHARACTERISTICS
|
|
|
Outer Conductor Integrity Temperature, Deg Celsius |
175 |
Maximum Operating Temperature, Deg Celsius |
150 |
|
Outer Conductor |
Tin plated Copper |
Dielectric |
PTFE |
Center Conductor |
SPCW |
|
|